10 - 8624-2 Standard
english
5.2 Changing the cable outlet direction
Unscrew the 4 screws on the front
panel of the flow pressure controller and
remove the cover carefully.
Remove the screw to the valve and
remove the plastic cross.
Detach the plate from the cube.
Pull out the cube downwards and
replace in the desired orientation.
Place the plate onto the cube (the pins
must engage in the guides).
Lay on the plastic cross and insert the
screw through the cube.
Connect the flow pressure controller to
the proportional valve (see 5.1).
Fig.: Changing the cable outlet direction