Operating Instructions
Bedienungsanleitung
Manuel utilisateur
Type 8041
Insertion electromagnetic flowmeter
Magnetisch-induktives Durchfluss-Messgerät, Insertion
Débitmètre électromagnétique à insertion
Vista de pagina 0
1 2 3 4 5 6 ... 59 60

Indice de contenidos

Pagina 1 - Type 8041

Operating InstructionsBedienungsanleitung Manuel utilisateurType 8041 Insertion electromagnetic flowmeterMagnetisch-induktives Durchfluss-Messgerät,

Pagina 2 - © Bürkert SAS, 2011 - 2013

8Technical data6. TECHNICAL DATA6.1. Conditions of useAmbient temperature -10 °C...+60 °CAir humidity < 80%, non condensatedProtection class acc.

Pagina 3

9Technical dataTable 2 : Parts not in contact with the fluidPart MaterialHousing, cover, nut• holder of the flow sensor in stainless steel• holder

Pagina 4

10Technical dataTable 3 : Dimension H in mm of the flowmeter 8041 with a G2" nut and inserted into an S020 fittingHT-fittingSaddleSpigot, in pla

Pagina 5 - 1. ABOUT THIS MANUAL

11Technical dataTable 4 : Dimension H in mm of the flowmeter 8041 with a clamp connection and inserted into an S020 fittingHT-fittingWelding socketDN

Pagina 6 - INFORMATION

12Technical data+10+30+50 +70021345678910P [bar]T [°C]PVDF (PN10) / MetalPVC + PPPVC (PN10)PP (PN10)Fig. 6: Fluid pressure-temperature dependency of

Pagina 7

13Technical dataCurrent output• Type of output• Accuracy• Refresh time• Max. loop impedance • 4-20 mA, sinking or sourcing wiring• ± 1% (0,16 mA

Pagina 8 - 5. DESCRIPTION

14Quick installation7. QUICK INSTALLATIONContact your Bürkert agent → Unpack the device.Order code correct? → Loosen 4 screws and remove cover.yesNo

Pagina 9 - 00552780

15Quick installation → Select the measuring range with switches 4 and 5, see chap. 9.6. → Thread the cables through the cable glands and make the con-

Pagina 10 - 6. TECHNICAL DATA

16INstallationGreen LED flashes once? → Put the cover on the device as dsecribed in Fig. 17, chap. 8.3. → Tighten the 4 screws of the cover in an alte

Pagina 11

17INstallationWarningRisk of injury due to non-conforming installation.• The electrical and fluid installation can only be carried out by qualified a

Pagina 12

We reserve the right to make technical changes without notice.Technische Änderungen vorbehalten.Sous réserve de modifications techniques.© Bürkert SAS

Pagina 13 - 6.4. General data

18INstallationExample: - Specification: if the nominal flow rate is 10 m3/hthe ideal flow velocity is between 2 and 3 m/s - Solution: intersection bet

Pagina 14 - 6.5. Electrical data

19INstallation → Install the device on the pipe to have the upstream and down-stream distances respected according to the design of the pipes, refer t

Pagina 15 - 6.7. K factors

20INstallationVertical mountingCorrect Incorrectflow directionFig. 10: Filling of the pipeCorrectflow directionIncorrectCorrect IncorrectFig. 11: Ai

Pagina 16

21INstallation8.2.3. Installation into the pipe of a 8041 with a clamp connectionObserve the installation recommendations described at chap. 8.2.1 an

Pagina 17

22INstallation1234564...20V+V-PEPls+Pls-CNONCBA213 Selector A: Sink/source selector of the 4-20 mA outputTerminal block 3Terminal 1: 4-20 mA outputTe

Pagina 18 - 8. INSTALLATION

23INstallationnoteThe device is not tight if only one or none of the cable glands is used• The device is only tight when the cable glands are either

Pagina 19 - 8041 on the pipe

24INstallation8.3.1. Wiring the 4-20 mA outputThe current output of the 8041 can be connected to a PLC or a valve, either in sourcing mode or in sink

Pagina 20

25INstallation1234564...20 V+ V- PE Pls+Pls-V+0VI8041InputFig. 20: PNP connection of the frequency output to a PLC6Pls-8041123454...20 V+ V- PE Pls+V

Pagina 21 - 18 x DN 5 x DN 15 x DN 5 x DN

26INstallation8.3.3. Wiring the relay outputThe relay output operates either in normally open mode (NO) or in normally closed mode (NC), depending on

Pagina 22

27Adjustment and commissioning+ -18-36 VDC250 VACLN300 mA3 A8041CNONC4...20 V+ V- PE Pls+Pls-*1 23456250 VAC, 3 A max.Power supplyProtection circuitRe

Pagina 23 - 8.3. Wiring

1 Type 80411. ABOUT THIS MANUAL ...31.1. Symbols used ...

Pagina 24 - 4...20V+V-PEPls+Pls

28Adjustment and commissioningWarningDanger due to non-conforming commissioning.Non-conforming commissioning can lead to injuries and damage the devic

Pagina 25 - 18-36 VDC

29Adjustment and commissioning1 2 3 4 5 64...20 V+ V- PE Pls+Pls-ON1 2 3 4 5 61 2 3 4 5 6 7 8 9 10Green LED:...Flashing once every second: the devic

Pagina 26

30Adjustment and commissioning9.3. General diagram of the Read and Parameterizing modesX 12Read modeParameterizing modeFlow zero calibrationFull scal

Pagina 27 - 4...20 V+ V- PE Pls+Pls

31Adjustment and commissioningXX...X221RelayShort pressShort pressShort pressShort pressCurrent way of switching*Current low switching threshold*Cu

Pagina 28 - 3 4 5 62

32Adjustment and commissioning9.4. Selecting the frequency of the main supplySwitch 1 is used to select the frequency of the current provided by the

Pagina 29 - COMMISSIONING

33Adjustment and commissioningFilter Position of switch 3slow (Response time 10 to 90 % = 14 s)OFFfast (Response time 10 to 90 % = 5 s)ON9.6. Select

Pagina 30

34Adjustment and commissioningNOYES → Press and hold the push button.After 2 s, device is in Parameterizing mode:... Bargraph alternates between:

Pagina 31 - 1 2 3 4 5 6 7 8 9 10

35Adjustment and commissioningA → Briefly press push button.To calibrate automatically → Press and hold the push button until...To select the calibrat

Pagina 32 - Parameterizing mode

36Adjustment and commissioning9.8. Calibrating the full scaleThe Fig. 30 and the Fig. 31 show the relation between the measured fluid velocity and th

Pagina 33

37Adjustment and commissioningNOYES → Press and hold the push button.After 2 s, device is in Parameterizing mode:... Bargraph alternates between:

Pagina 34 - 9.5. Filter selection

2 Parameterizing modes ... 309.4. Selecting the frequency of the main supply ...

Pagina 35

38Adjustment and commissioningCalibration in progress → Press and hold the push button until...To select the calibration of the other parameterBA → B

Pagina 36 - → Release push button when

39Adjustment and commissioning9.9. Setting the parameters of the relay outputThe Fig. 34 shows the behaviour of the relay output depending on the par

Pagina 37

40Adjustment and commissioningThe wiring of the relay determines the function of the relay: Normally Open (NO) or Normally Closed (NC).The following p

Pagina 38

41Adjustment and commissioningState of the relay outputdeactivatedactivedLow threshold High thresholdm/sFig. 38: Change of state of the relay output

Pagina 39

42Adjustment and commissioning → Briefly press push button. → Press and hold the push button until... → Wait for 10 s. → Release push button when barg

Pagina 40 - → Wait for 10 s

43Adjustment and commissioningNOSee general configu-ration diagram, chap. 9.3Device in Read mode?... YESATo view low switching threshold 1 2 3 4 5

Pagina 41

44Adjustment and commissioning → Release the push button when desired number of LEDs is on.To set the units for the low switching threshold. → Briefly

Pagina 42

45Adjustment and commissioning → Briefly press push button. → Press and hold the push button → Wait for 10 s.To confirm the selection and go back to R

Pagina 43

46Adjustment and commissioningNotation convention: ...Green LED stateRed LED stateNOYESSee general con-figuration diagram, chap. 9.3Device in Read m

Pagina 44

47Adjustment and commissioning → Briefly press push button.To go back to Read mode without confirming the value set. → Wait for 10 s.BD → Press and ho

Pagina 45

3About this manual1. ABOUT THIS MANUALThis manual describes the entire life cycle of the device. Please keep this manual in a safe place, accessible

Pagina 46

48Maintenance and troubleshooting10. MAINTENANCE AND TROUBLESHOOTING10.1. Safety instructionsdangerRisk of injury due to high pressure in the instal

Pagina 47 - → Release the push button

49Maintenance and troubleshooting10.4. Replacing the seal on a device with G2" nutnote Do not scratch the seal groove.123Seal Groove Fig. 47: D

Pagina 48

50Maintenance and troubleshootingProblemBargraph stateRed LED stateGreen LED stateCurrent or frequency output stateMeaning / Cause Recommended actionT

Pagina 49

51Maintenance and troubleshootingProblemBargraph stateRed LED stateGreen LED stateCurrent or frequency output stateMeaning / Cause Recommended actionT

Pagina 50 - TROUBLESHOOTING

52Maintenance and troubleshootingProblemBargraph stateRed LED stateGreen LED stateCurrent or frequency output stateMeaning / Cause Recommended actionT

Pagina 51

53Spare parts and accessories11. SPARE PARTS AND ACCESSORIESattentionRisk of injury and/or damage caused by the use of unsuitable parts.Incorrect acc

Pagina 52

54StorageSpare parts Order codeSet of: - 1 stopper gasket for an M20 x 1,5 cable gland - 1 multi-way seal, 2 x 6 mm, for a cable gland56538412. PACK

Pagina 53

55 EnglishType 8041

Pagina 54

56 EnglishType 8041

Pagina 56 - 14. DISPOSAL OF THE DEVICE

4Intended use2. INTENDED USEUse of the device that does not comply with the instructions could present risks to people, nearby installations and the

Pagina 57

www.burkert.com

Pagina 58

5Basic safety informationVarious dangerous situations (cont'd)To avoid injury take care:• not to use the device for the measurement of gas flow

Pagina 59

6General information4. GENERAL INFORMATION4.1. Manufacturer's address and international contactsTo contact the manufacturer of the device, use

Pagina 60

7DescriptionWhen the fluid flows over them, a voltage is measured between the two electrodes. This voltage is proportional to the fluid velocity.Fig.