8625-2 Standard - 9
english
5.2 Changing the cable outlet direction
Î Unscrew the 4 screws on the front panel
of the temperature controller and remove
the cover carefully.
Î Remove the screw to the valve and
remove the plastic cross.
Î Detach the plate from the cube.
Î Pull out the cube downwards and replace
in the desired orientation.
Î Place the plate onto the cube (the pins
must engage in the guides).
Î Lay on the plastic cross and insert the
screw through the cube.
Î Connect the temperature controller to the
proportional valve (see 5.1).